FECS Laboratory provides testing and technical services for research and industry. Browse our services, select what you need and send an inquiry. Every request is subject to technical and safety review, sample suitability, and laboratory availability.
Our Laboratory Advantage
As part of the Faculty of Engineering, Computing and Science at Swinburne University of Technology Sarawak Campus in Kuching, FECS Laboratory supports teaching, research and industry through a range of testing and technical services. Our capabilities span chemical, mechanical, civil, robotics and mechatronics, and electrical and electronics engineering. Our technical team will review your enquiry and advise on test feasibility, sample suitability, sample requirements and the appropriate next steps.
ACCREDITATION
MS ISO/IEC 17025:2017 (SAMM No. 1227)
SERVICES
19 testing services across 5 disciplines
LOCATION
Kuching, Sarawak, Malaysia
Accredited scope | Testing services | How it works | Send an inquiry
FECS Laboratory is accredited to MS ISO/IEC 17025:2017 under the Skim Akreditasi Makmal Malaysia (SAMM), SAMM No. 1227. Accreditation applies only to the specific tests, materials or products, measured properties, ranges and methods listed in the laboratory’s current approved scope of accreditation.
Material
Foods; Agricultural Products and Materials
Method
In-house Method SUTS.FECS.WI.114 based on Bomb Calorimeter C-200
Equipment
IKA C200 Bomb Calorimeter, 40 kJ
Material
Metallic Materials
Method
ISO 6892-1: Metallic Materials – Tensile Testing – Part 1: Method of Test at Room Temperature
Equipment
Shimadzu AG-100kN XPLUS
Note: Accreditation applies to the complete combination of material or product, test and approved method, not to every test run on the same equipment.
Scope source: SAMM 1227, Issue 2 (replacement of SAMM 463 dated 11 June 2025); schedule issue date 17 November 2025; valid until 17 November 2030.
Select a service and use Email inquiry to open a pre-addressed email.
Simultaneous Thermal Analysis
Perkin Elmer STA 8000 TG with DTA + DSC mode, temperature range 15°C to 1600°C
Email inquiry
FTIR Spectroscopy - ATR
Perkin Elmer Spectrum 3 MIR, 8,300 - 30 cm⁻¹
Email inquiry
UV-Visible Spectroscopy
Perkin Elmer Lambda 35 double beam, wavelength 190 - 1100 nm
Email inquiry
Bomb Calorimetry (Accredited test available; see Accredited scope)
IKA C200, 40 kJ
Email inquiry
Gas Chromatography - FID
Agilent 7890 GC System
Email inquiry
Gas Chromatography - TCD
Agilent 7890 GC System
Email inquiry
Planetary Ball Milling
Fritsch Pulverisette 6, 650 rpm, 225 mL
Email inquiry
Rotor Milling
Fritsch Pulverisette 14, 6,000 - 20,000 rpm, feed particle size 10 mm max
Email inquiry
Vibratory Sieve Analysis
Fritsch Analysette 3 PRO, dry sieving 20 µm - 63 mm, wet sieving 20 µm - 10 mm
Email inquiry
Universal Testing Machine
Go-Tech AI-7000L, 50 kN
Email inquiry
Field Emission Scanning Electron Microscopy (FESEM)
Hitachi SU8700, magnification 20X to 2,000,000X, resolution up to 0.8 nm @ 15 kV
Email inquiry
FESEM with Energy-Dispersive X-ray Spectroscopy (EDS)
Hitachi SU8700 with Oxford EXPLORE 30
Email inquiry
Sputter Coating
Magnetron MSP-15
Email inquiry
Universal Testing Machine - 100 kN (Accredited test available; see Accredited scope)
Shimadzu AG-100kN XPLUS, 100 kN
Email inquiry
Compression Testing
MATEST C089-02, 2000 kN
Email inquiry
Compression and Flexural Testing
MATEST C091-02, 150 kN
Email inquiry
3D Printing
BambuLab X1 Carbon Combo PF001-P (filament not included)
Email inquiry
Laser Cutting
CMA6040-B-A, working area 400 x 600 mm (acrylic only; cutting service only, material not included)
Email inquiry
RF Signal Generation
Agilent Technologies E8267D, 200 kHz - 1 GHz
Email inquiry
Submission of an inquiry does not confirm acceptance of a testing job. Do not send samples until written acceptance and sample-submission instructions are received.
[email protected]
Kuching, Sarawak, Malaysia
Rates are provided on request after technical assessment.
FECS Laboratory is accredited to MS ISO/IEC 17025:2017 under SAMM No. 1227, with accreditation limited to the current approved scope. Information sent is used only to respond to the inquiry.